Introduction and objectives: To assess differences in visual performance after implantation of two extended depth of-focus simultaneous vision intraocular lenses (IOLs) with different optical designs.
Patients and methods: A randomised prospective comparative interventional study in patients requiring cataract surgery for both eyes. Patients were divided into two groups: one given biconvex IOLs (Tecnis EyhanceTM, Johnson & Johnson Vision Care, Inc, Jacksonville, FL, USA) and the other inverted meniscus IOLs (ArtIOLsr25,
Voptica, Murcia, Spain). One month after the surgical intervention in the second eye, the binocular distance corrected visual acuity was measured at far, intermediate (66 cm), and near (40 cm) distances. Additionally, binocular distance-corrected defocus curves were obtained. Potential correlations of intermediate visual acuity (VA) with corneal spherical aberration (Z4 ∘) and pupil size were explored. The Catquest-9SF questionnaire was administered to all patients to assess their vision-related quality of life after IOL implantation.
Results: Overall, 30 patients (60 eyes) were assessed. Binocular distance corrected intermediate visual acuities of 0.20 logMAR (0.10;0.30) (p = 0.445), were achieved in both groups. The binocular distance corrected near visual acuity was 0.3 logMAR (0.25; 0,40) in the Tecnis EyhanceTM group and 0.4 logMAR (0.30;0.50) in the ArtIOLsr25 group (p = 0.050). Intermediate visual acuity was weakly correlated with corneal spherical aberration and pupil size. The Catquest-9SF score was close to 1 in both groups, but better in the Eyhance group, and the difference was statistically significant (p = 0.035).
Conclusions: Both the Tecnis EyhanceTM and ArtIOLsr25 IOLs achieved a binocular distance-corrected intermediate VA of 0.2 logMAR, without compromising distance VA. No differences were observed between the two groups in the outcomes experienced by patients in their daily lives related to their vision problems after cataract surgery.
Search
Categories
Archives
- April 2026 (1)
- February 2026 (1)
- December 2025 (2)
- October 2025 (7)
- June 2025 (2)
- May 2025 (1)
- March 2025 (4)
- December 2024 (4)
- October 2024 (5)
- September 2024 (1)
- July 2024 (8)
- June 2024 (1)
- May 2024 (1)
- March 2024 (1)
- October 2023 (2)
- July 2023 (5)
- June 2023 (1)
- July 2022 (10)
- May 2022 (1)
- March 2022 (1)
- July 2021 (5)
- March 2021 (2)
- October 2020 (36)
- September 2020 (122)
- August 2020 (10)
- July 2020 (38)
- April 2020 (1)
- December 2019 (1)
- April 2018 (1)
- September 2017 (2)
Assessment of visual performance and quality of life obtained with twoextended depth of focus simultaneous vision lens platforms
- Voptica
- ArtIOLs Publications
Journal:
Archivos de la Sociedad Española de Oftalmología
Year:
2026
Authors:
B. de Luis Eguileor, B. Santos Zorrozúa, J. Etxebarria Ecenarro